nTier700 BlueScale Firmware Firmware Package History
July 2012 Release Notes—Spectra nTier700 Backup and Archive Appliance
18
Known Issue
BlueScale2.6.0.6
ThisfirmwarereleaseimprovesoverallreliabilityofthenTier700.
Resolved Issues
DisconnectingandreconnectingthecablestotheEthernetportsonthe
nTier700backpanelnolongercausesthesystemtohang.
Known Issues
Problem Workaround
WhenRAIDsarerebuilding,the
Bluescaleprogressscreendoesnot
updatetoreflecttheactualprogress,
evenwhentheprocessisnearly
complete.
Note: Thisissueisresolvedin
BlueScale2.7.1.7.
IfyouneedtodeterminethestatusoftheRAIDrebuild,do
oneofthefollowing:
MonitortheBlueScalemessages.The
rebuildiscomplete
whenyouseeamessagesimilartothis:
Raid <raid name> in Enclosure <Enclosure
#> Chassis <Chassis #> Hba <Hba #>
Expander <Expander #> changed state from
<previous state> to OK
UsetheWindowscommandlinetodetermine thestatus.
1. ConnecttotheWindowsdesktop.
2. Select Start > Accessories > Command Prompttoopena
commandpromptwindow.
3. Typethefollowingcommand:
%ntiercurrent%\adaptec\arcconf.exegetstatus<ctrl#>
where
<ctrl #>
isthenumberoftheRAIDcontrolleron
whichtheRAIDwasbeingrebuilt(either1or2).
4. RepeatStep2untilthestatusreturnedis“None.”
Problem Workaround
UpdatefromBlueScale2.2or2.3 to2.6 .0.6fails
unlessspecificproceduresarecarefullyfollowed.
ThisupdatemustbeperformedbySpectraLogic
TechnicalSupportpersonnel(seeContacting
SpectraLogiconpage 4).
AfterdisablingaNICthroughtheBlueScaleweb
interface,theoperatorpanelnolongeroperates
correctly.
Donotdisable
NICs.
FollowingarebootofthenTier700,theBlueScale
webinterfaceshowsthestatusforallsystem
componentsasunknownandLastUpdateasold.
Note: ResolvedinBlueScale2.9.0.4.
Rebootthesystemagain.
Komentarze do niniejszej Instrukcji